ALU 150
219
3.4 Starting Behavior of the Controller
With the aid of the jumper M, contact pin ”set” and in combination with the UKA 024 or
SCU 150 the starting behavior of the controller may be defined after a voltage failure.
For more information on configuration see chapter ”Startup Characteristics” in the user
manual.
3.5 Documentation
An A3 form sheet with explanations is available for the system documentation, showing
which type and E-No. is set for the software used as well as the operating conditions of
jumpers and switches. These form sheets are:
part of the form pad intended for conventional processing (see ordering details)
part of the Ruplan processing database (under development) and intended for
Ruplan processing (technical sales office version)
4 Specifications
4.1 Allocation
Devices A350, A500
Structure Designated slot in the primary subrack (see module de-
scription of the subrack)
4.2 Supply Interface
Internal
UB 5 +5 V/1.4 A typical (2.5 A max)
UB 12 +12 V/0.1 A typical (0.15 A max)
UB -12 -12 V/10 mA typical (15 mA max)
Reference Potential 0 V
4.3 Data Interface
PEAB Parallel in-/output bus
PMB Parallel microprocessor bus, driver design for max.
12 PMB subscribers
RS 232C / V.28 Serial interface according to DIN 66 020, non-isolated
connection via SCU 150 on A350 or UKA 024 on A500
4.4 Processor Type
8086 Microporcessor (16 bit) for logic and arithmetic
8087 Expansion of the module by adaptation of the additional
board MAT 827 for processing numerical-mathematical
problems