3.1.2 Changeover Tesy
SEAB Networking
T/S changeover to program Tesy or SEAB networking
3.1.3 Relay Signal M5
If the M5 signal is ”On” when wire break occurs, the jumper must not be plugged in on
the labelled side, in reverse case on the MN labelled side. For current loop operation
the jumper must be plugged in on the unlabelled side.
3.1.4 Interrupt P
The interrupt to the PMB can alternatively be switched to the MSPFN (parity error) or to
the MPARN (address).
Jumper between middle and bottom: interrupt is switched to MSPFN
Jumper between top and middle: interrupt is switched to MPARN
No jumper: no interrupt
3.1.5 Status Bit (B0N, B5N)
These jumper settings can be read via address I and I/O to data bit 0 and data bit 5.
B0, B5 Jumper between middle and bottom: valence ”0”
Jumper between top and middle: valence ”1”
On data bit 6 the interrupt memory state FF-CPU, i.e. interrupt of the CPU can be read.
On data bit 7 the interrupt memory state FF-PMB, i.e. interrupt of the PMB can be read.
T
S
MN
P
B0N B5N