CAUTION
The pulled plug has mains voltage of the load circuit! The new connecting lines must be fused
according to the applicable regulations (for applicable plug, see chapter 13).
4.3 POWER SUPPLY FOR THE VENTILATOR
With Thyro-P Thyristor Power Controllers furnished with integrated ventilators (HF types), the venti-
lator must be supplied with a voltage of 230V 50/60Hz according to the connecting plans and the
dimensional drawings. The ventilator’s power consumption is given in chapter 11 TECHNICAL
DATA.
ATTENTION
The ventilator must run when the Power Controller is switched on.
4.4 RESET
The input RESET (terminals X5.2.12-X5.1.14) is separated from the remaining system by an opto-
electronic coupler. By opening the RESET jumper the Thyristor Power Controller is locked (load:
24V/20mA), i.e. the power sections are no longer triggered. On activating RESET, LED “ON” lights
up red.
Functional procedure:
TERMINALS FUNCTION
X5.12-14 closed Enables the device
X5.12-14 open Device is out of operation, communication via interfaces not possible
TAB. 8 RESET
The hardware RESET must be applied when synchronizing the software of several Power Controllers
(chapter 6.3 SOFTWARE SYNCHRONIZATION). If the Power Controller is equipped with a Bus
option, a Bus RESET also ensues from the hardware RESET. Apart from opening the jumper terminal
X5.2.12-X5.1.14, the hardware RESET is also activated by supply voltage OFF or by reducing the
supply voltage at the Power Controller (A70-X1) to below 160V.
4.5 CONTROLLER INHIBIT
The input controller lock (terminals X5.2.15 and X5.1.14) is electrically identical to the input RESET
(electrical data as under 4.4.).
ATTENTION
When activating controller lock, the LED „PULSE LOCK“ is lit and the control device remains com-
pletely in operation. The total set point is therefore without effect, but the min. limiting values (TS-
MIN, HIME) remain active. This enables securing a certain quantity of electrical energy at the load.
TERMINALS FUNCTION
X5.15-14 closed power controller operating
X5.15-14 open control pulses OFF (default value) or pulse limit
TAB. 9 CONTROLLER LOCK
All other functions of the power controller remain in operation. The state of the signalling relay
does not change (parameter-dependent) and communications remains active. After closing the
controller lock jumper, the controller is back in operation.
4.6 QUIT
The input acknowledge (Quit, X5.2.19) has a circuit identical with the input RESET. It must be
Page view 47
1 2 ... 43 44 45 46 47 48 49 50 51 52 53 ... 111 112

Comments to this Manuals

No comments

Ce-niehoff-co N1224 Alternator Regulator Changeout Instructions manuels

Manuels d'utilisation et guides de l'utilisateur pour Matériel Ce-niehoff-co N1224 Alternator Regulator Changeout Instructions.
Nous fournissons des manuels en pdf 1 Ce-niehoff-co N1224 Alternator Regulator Changeout Instructions à télécharger gratuitement par type de document : Manuel de l'utilisateur






Plus de produits et de manuels pour Matériel Ce-niehoff-co

Modèles Type de document
N1128-1 Alternator w/Link or w/Wiring Harness Inst Manuel de l'utilisateur   C.E. Niehoff & Co. N1128-1 Alternator w/Link or w/Wiring Harness Installation User Manual, 2 pages
N1211, N1211-2(N3106), N1211-4 (N3116), N1211-5 (N Manuel de l'utilisateur   C.E. Niehoff & Co. N1211, N1211-2(N3106), N1211-4 (N3116), N1211-5 (N3121) Installation User Manual, 2 pages
N1224-1 thru -6 Installation Manuel de l'utilisateur   C.E. Niehoff & Co. N1224-1 thru -6 Installation User Manual, 1 pages
N1235-1 Alternator/N3134 Regulator Installation Manuel de l'utilisateur   C.E. Niehoff & Co. N1235-1 Alternator/N3134 Regulator Installation User Manual, 2 pages
N1225/N1387 Alternator Installation Manuel de l'utilisateur   C.E. Niehoff & Co. N1225/N1387 Alternator Installation User Manual, 2 pages
N1234-1 Alternator Installation Manuel de l'utilisateur   C.E. Niehoff & Co. N1234-1 Alternator Installation User Manual, 1 pages
N1235-1 B+ Terminal Stud Replacement Instructions Manuel de l'utilisateur   C.E. Niehoff & Co. N1235-1 B+ Terminal Stud Replacement Instructions User Manual, 1 pages
N1240-2/3 & N1243-2/6 Alternators Installation Manuel de l'utilisateur   C.E. Niehoff & Co. N1240-2/3 & N1243-2/6 Alternators Installation User Manual, 1 pages
N1235: N7074 ADE Housing Replacement Instructions Manuel de l'utilisateur   C.E. Niehoff & Co. N1235: N7074 ADE Housing Replacement Instructions User Manual, 2 pages
N1241-1 Alternator/N3208 Regulator Installation Manuel de l'utilisateur   C.E. Niehoff & Co. N1241-1 Alternator/N3208 Regulator Installation User Manual, 2 pages
N1307/N1307-1 Alternators Installation Manuel de l'utilisateur   C.E. Niehoff & Co. N1307/N1307-1 Alternators Installation User Manual, 1 pages
N1385-2 Alternator Installation Manuel de l'utilisateur   C.E. Niehoff & Co. N1385-2 Alternator Installation User Manual, 1 pages
N1381: N7300 Replacement Kit Instructions Manuel de l'utilisateur   C.E. Niehoff & Co. N1381: N7300 Replacement Kit Instructions User Manual, 2 pages
N1375: N7289 DE Housing Installation Manuel de l'utilisateur   C.E. Niehoff & Co. N1375: N7289 DE Housing Installation User Manual, 4 pages
N1304-1 to N1380-2: N7359-1 Conversion Kit Instruc Manuel de l'utilisateur   C.E. Niehoff & Co. N1304-1 to N1380-2: N7359-1 Conversion Kit Instructions User Manual, 5 pages
N1387 Alternator/EPM Operating Reference Card Manuel de l'utilisateur   C.E. Niehoff & Co. N1387 Alternator/EPM Operating Reference Card User Manual, 2 pages
N1501 Alternator Installation Manuel de l'utilisateur   C.E. Niehoff & Co. N1501 Alternator Installation User Manual, 1 pages
N1505-1 Alternator/N3226N3135 Regulator Installati Manuel de l'utilisateur   C.E. Niehoff & Co. N1505-1 Alternator/N3226N3135 Regulator Installation User Manual, 2 pages
N1509-2 Alternator Installation Manuel de l'utilisateur   C.E. Niehoff & Co. N1509-2 Alternator Installation User Manual, 2 pages
N1388: N7153 Control Unit Assembly/ N7155 B+ Outpu Manuel de l'utilisateur   C.E. Niehoff & Co. N1388: N7153 Control Unit Assembly/ N7155 B+ Output Stud Replacement Instructions User Manual, 2 pages