AEG 381 D Specifications Page 74

  • Download
  • Add to my manuals
  • Print
  • Page
    / 80
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 73
74
© Systeme Lauer GmbHAEG250PX-Expander driver
D
FB212:
NETWORK: 1
NAME :AND_FUN
:***
NETWORK: 2
:L COUNT_W ;update data word counter
:SUB K 1
:SUB DW_COUNT_W
:= COUNT_W ¦
:L P_DAT_OFF ;pointer actual pcs data
:ADD ADR_W
:= ADR_W
:L PJOB_W ;actual job
:ADD K 1
:= PJOB_W ;pointer to received data
AND_LP:BA LA5 ;received data
NAME :LA5
IN : PJOB_W
OUT : TEMP1_W
:BA LA5 ;plc data
NAME :LA5
IN : ADR_W
OUT : TEMP2_W
:L TEMP2_W ;and function between plc data
:U TEMP1_W ;and received data
:= TEMP1_W
:BA LA4 ;actual data to data buffer
NAME :LA4
IN : TEMP1_W
OUT : ADR_W
:L ADR_W ;increment data pointer
:ADD K 1
:= ADR_W
:L PJOB_W ;pointer to next data
:ADD K 1
:= PJOB_W
:L DW_COUNT_W ;decrement counter received data
:SUB K 1
:= DW_COUNT_W
:SPN =AND_LP ;until datacounter <> 0
:***
NETWORK: 3
:BE
Signal Symbol
MW4 COUNT_W
MW7 DW_COUN_W
MW4 COUNT_W
MW1 P_DAT_OFF
MW5 ADR_W
MW5 ADR_W
MW3 PJOB_W
MW3 PJOB_W
SFB139 LA5
MW3 PJOB_W
MW10 TEMP1_W
SFB139 LA5
MW5 ADR_W
MW11 TEMP2_W
MW11 TEMP2_W
MW10 TEMP1_W
MW10 TEMP1_W
SFB138 LA4
MW10 TEMP1_W
MW5 ADR_W
MW5 ADR_W
MW5 ADR_W
MW3 PJOB_W
MW3 PJOB_W
MW7 DW_COUN_W
MW7 DW_COUN_W
Printout of the AEG250PX handlingsoftware
Page view 73
1 2 ... 69 70 71 72 73 74 75 76 77 78 79 80

Comments to this Manuals

No comments