© Systeme Lauer GmbH AEG250PX-Expander driver
D
D1.2.1 PCS midi driver variables
Seven variables can be set for the AEG250PX driver in the PCSPRO software under
the menu item Project/Driver Parameter.... The content of the variables can be
examined with the PCS offline menu.
1 AA variable: PCS Time-out time
The time-out time determines the maximum admissible time for the order processing
of the synchronization word in the programmable controller. Default value for this
time is 4000. This corresponds to 4000 ms. = 4.0 seconds. Admissible values for
the variable are from 2000 to 19990. This corresponds to 2 to 19.99 seconds.
2 - 5 AC, AD, AE and AF variables: Baud rate and transfer type
The baud rate and interface, the PCS and the programmable controller use for
communication are set with the PCS DIL-switches 5 and 6. Here, you select the
same settings that you have selected in PCSPRO under the DRIVER VARIABLES
menu item. The default settings are shown In the table below.
DIL5 DIL6 Variable Preset values
off off AC 19200 Baud
on off AD 9600 Baud
off on AE 19200 Baud
on on AF 9600 Baud
All baud rates and transfer types that can be selected using the DIL-switches are
shown in the following table.
Interface Baud rate
RS 232 19200
RS 232 9600
6 AG variable: Send/receive buffer
Determines the first used flag word in the programmable controller for the data
interchange area. Thereby, the variable has an offset function. Possible values
are from 1 to 15000. The default setting for the flag word is 1256.
7 AJ variable: Task per package
Determines the number of the sub-packages for the data interchange. The default
setting is AJ = 50. If AJ is reduced, then the transfer time of tasks with high priority
is decreased (e.g. key tasks). Tasks with lower priority (e.g. present values) will be
transferred correspondingly less often.
During configuration of the PCS, both the application program with data and a
selected driver are transferred. The driver is called AEG250PX.DRV.