Accessories: Hardware
Hardware: Extensions & accessories
Manual bypass switch for maintenance and
battery tests
Parallel board, manual bypass and distribution
Manual Bypass Switch
Power Distribution Box
Part numbers Remote Panel # 600 000 5881 PDU 10-1 # 600 000 6684 MBS 2000 # 600 000 3039 PDB for Protect C. # 100 000 1852
PDU 16-1 # 600 000 6829 MBS 3000 # 600 000 3040 PDB for Protect 1. # 100 000 1853
PDU 10-2 # 600 000 6831 MBS 6000 Rack # 600 000 5205
PDU 16-2 # 600 000 6832 MBS 10000 # 600 000 7684
IEC Distribution Bar # 600 000 9254 MBS 24000 # 100 000 2021
The external manual bypass switch, an optional add-on for the
Protect B., B. PRO, C., C.R, D., 1. and 1.M series of UPS systems,
is used to bypass a UPS for example, to carry out mainte-
nance – without interrupting the supply of power to connected
loads. Besides simple bypass operation, it features an additional
setting to enable UPS testing. The switch is equipped with indi-
vidually protected power connectors to supply power to loads
directly.
The external manual bypass switch has three settings:
1. UPS mode: Loads are supplied with power via the UPS.
2. Service mode: Connected loads are powered directly from
the mains supply. This setting also enables the UPS to be
tested.
3. Bypass mode: In this mode, loads are powered directly from
the mains supply. The attached UPS is fully disconnected from
the circuit and can be removed for maintenance or replace-
ment.
With the compact parallel switch panel, users can set up a paral-
lel system comprising up to three Protect C.6000 / C.10000 or
up to three Protect 1.100 / 1.150 or 1.200 units without needing
to restructure an existing low-voltage main distribution system.
Combining up to 24 separately protected, ready-made circuits
in an output distribution unit built into a parallel switch panel,
the PDB box eliminates the need to set up or reorganize a sub-
distribution system.
Offering active redundancy and designed for use with the Protect
C. range of single-phase UPS units (up to 30 kVA or 20 kVA) and
the Protect 1. range of three-phase-input UPS units (up to 60
kVA or 40 kVA), the switch panel allows users to connect devices
in parallel for enhanced performance and single or multiple
redundancy. Each UPS unit can be disconnected from the mains
supply on the input side and from the protected busbar with-
out interrupting the supply of power to connected loads. In addi-
tion, the manual bypass can disconnect the entire parallel UPS
system – for maintenance, for example –without cutting power
to attached devices. A remote signaling contact indicates the
current operating status.