Page view 17
Problem and alarm code Possible cause and solution
The appliance does not fill
with water.
The display shows .
Make sure that the water tap is open.
Make sure that the pressure of the water supply is not
too low. For this information, contact your local water
authority.
Make sure that the water tap is not clogged.
Make sure that the filter in the inlet hose is not clogged.
Make sure that the inlet hose has no kinks or bends.
The appliance does not
drain the water.
The display shows .
Make sure that the sink spigot is not clogged.
Make sure that the filter in the outlet hose is not clog-
ged.
Make sure that the interior filter system is not clogged.
Make sure that the drain hose has no kinks or bends.
The anti-flood device is on.
The display shows .
Close the water tap and contact an Authorised Service
Centre.
The appliance stops and
starts more times during op-
eration.
It is normal. It provides optimal cleaning results and en-
ergy savings.
The program lasts too long. Select the time-saving option to shorten the program
time (if applicable).
If the delayed start option is set, cancel the delay setting
or wait for the end of the countdown.
The remaining time in the
display increases and skips
nearly to the end of program
time.
This is not a defect. The appliance is working correctly.
Small leak from the appli-
ance door.
The appliance is not level. Loosen or tighten the adjust-
able feet (if applicable).
The appliance door is not centred on the tub. Adjust the
rear foot (if applicable).
The appliance door is diffi-
cult to close.
The appliance is not level. Loosen or tighten the adjust-
able feet (if applicable).
Parts of the tableware are protruding from the baskets.
Rattling/knocking sounds
from inside the appliance.
The tableware is not properly arranged in the baskets.
Refer to basket loading leaflet.
Make sure that the spray arms can rotate freely.
The appliance trips the cir-
cuit-beaker.
The amperage is insufficient to supply simultaneously all
the appliances in use. Check the socket amperage and
the capacity of the meter or turn off one of the applian-
ces in use.
Internal electrical fault of the appliance. Contact an Au-
thorised Service Centre.
www.aeg.com18