AEG L61470BI User Manual Page 22

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 21
To clean the water inlet filters:
1.
Close the water tap.
2.
Remove the water inlet hose from
the water tap.
3.
Clean the filter in the inlet hose with
a stiff brush.
4.
Remove the inlet hose behind the
appliance.
5.
Clean the filter in the valve with a
stiff brush or a towel.
45°
20°
6.
Install again the inlet hose. Make
sure that the couplings are tight to
prevent leakages.
7.
Open the water tap.
11.8 Emergency emptying out
If the water is not discharged, proceed
as follows to empty out the appliance:
1.
pull out the plug from the power
socket;
2.
close the water tap;
3.
if necessary, wait until the water has
cooled down;
4.
place a bowl on the floor;
5.
place the end of the emergency
emptying hose into the bowl;
6.
Remove its cap. The water should
drain by gravity into the bowl. When
the bowl is full, put the cap back on
the hose. Empty the bowl;
Repeat the procedure until water
stops flowing out;
7.
clean the pump if necessary as previ-
ously described;
8.
replace the emergency emptying
hose in its seat after having plugged
it;
9.
screw the pump again.
11.9 Frost precautions
If the machine is installed in a place
where the temperature could drop be-
low 0°C, proceed as follows:
1.
close the water tap;
2.
unscrew the water inlet hose from
the tap;
3.
place the end of the emergency
emptying hose and that of the inlet
hose in a bowl placed on the floor.
Let water drain out;
4.
screw the water inlet hose back on;
5.
put the cap on the emergency emp-
tying hose again;
6.
reposition the emergency emptying
hose.
22
www.aeg.com
Page view 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 35 36

Comments to this Manuals

No comments