Protect D.
for rack usage.
Classification VFI SS 211 acc. to IEC 62040-3 D. 1000 D. 1500 D. 2000 D. 3000
Type rating 1000 VA 1500 VA 2000 VA 3000 VA
900 W 1350 W 1800 W 2700 W
Part number (UPS) 600 000 8434 600 000 8436 600 000 8437 600 000 8438
Part number (BatteryPack) 600 000 8441 600 000 8442 600 000 8443
UPS INPUT
Nominal input voltage 200 Vac/230 Vac/240 Vac
Voltage range w/o battery operation (load-dependent) 160–276 Vac 180–276 Vac
Frequency (automatic detection) 50 Hz/60 Hz
±
10%
Mains current (system disturbance factor) λ 0.99 (THDi 8%)
Current consumption at full load (max.) 5 A 7.5 A 10 A 14 A
UPS OUTPUT
Rated output voltage (adjustable) 208 Vac / 220 Vac / 230 Vac (default) / 240 Vac
±
2 %
Frequency in battery/converter mode 50 Hz/60 Hz
±
0.25 Hz
Nominal output current (at 230 Vac) 4.3 A 6.5 A 8.7 A 13 A
Changeover time at mains failure 0 ms (without interruption)
Voltage curve shape sinusoidal, distortion THD < 3 %
Overload ability (double-conversion mode) < 130% for 5 min. / 130% - 150% for 15 s
Overload ability (battery mode) < 130% for 12 s / 130% - 150% for 2 s
Crest factor 3 : 1
Short circuit ability short-circuit-proof ( 4 x In for 100ms)
BATTERY
Type sealed, maintenance-free, lead acid, integrated, hot-swappable
Nominal DC voltage (intermediate circuit) 36 Vdc 48 Vdc 72 Vdc
Battery management
temperature compensated with discharge protection, autom. battery test & battery pack detection
Charging time (to 90 % of rated capacity) 3 h
COMMUNICATION
Interfaces RS232, USB, communication slot (can be used parallel to RS232/USB),
terminals for EPO and a potential-free contact
Shutdown software (on CD) five network licences included (Windows, Linux, Mac, Unix, Sun etc.)
Alarms (acoustical/optical) 3 LEDs arranged for quick operational status check, detailled indication via LCD display,
(alarms at mains failure, overload, battery discharged, replace battery, fan fault, RTC event logger)
GENERAL DATA
Efficiency at full load (ECO+ mode) 95 % 98 %
Efficiency at full load (double-conversion mode) > 88 % > 89 % > 90 %
Operating temperature range 0° to 40° C
Inherent noise (1 m distance/full load) < 45 dB (A) < 52 dB (A)
Humidity < 95% (without condensation)
EMC conformity EN 62040-2 Class C1, EN 61000-3-2, EN 61000-3-3
Product safety EN 62040-1
Max. site altitude up to 3000 m at full load
Load outputs Rack 6 x IEC320 C13 (2+2)
8 x IEC 320 C13 (2+2)
6 x IEC 320 C13 (3+3)
+ 1 x IEC 320 C19
Casing Material Metal case with Aluminium front
Dimensions W x H x D (mm) Rack 482.6 (19") x 88 (2U) x 430 482.6 (19") x 88 (2U) x 600
Battery 482.6 (19") x 88 (2U) x 430 482.6 (19") x 88 (2U) x 600
Weight approx. Rack 16 kg 19.5 kg 29 kg 29.5 kg
Battery 23 kg 28 kg 41 kg 41 kg
Delivery scope mains input cable (1 x EU, 1 x UK), UPS management software „CompuWatch” (CD),
communication cables (RS232 & USB), operating and safety instructions
device connection cables 3 x IEC320 C13 (D.1000-D.2000), 3x IEC320 C13 + 1 x IEC320 C19 (D.3000)
Conformity CE
Page view 30
1 2 ... 26 27 28 29 30 31 32 33 34 35 36 ... 51 52

Comments to this Manuals

No comments