Classification VFI SS 211 acc. to IEC 62040-3 C. 1000 C. 2000 C. 3000
Classification VFI SS 111 acc. to IEC 62040-3 C. 6000 C. 10000
Type rating 1000 VA 2000 VA 3000 VA 6000 VA 10000 VA
700 W 1400 W 2100 W 4200 W 7000 W
can be operated in parallel mode
Part number (Tower) 600 000 5735 600 000 5736 600 000 5738 600 000 5877 600 000 5878
Part number (BatteryPack) 600 000 5739 600 000 5740 600 000 5740 600 000 5879 600 000 5880
Part number (Tower S-Version) 600 000 4337 600 000 4338 600 000 4339 600 000 4340 600 000 4341
UPS INPUT
Input voltage 220 Vac/230 Vac/240 Vac
Input voltage range without battery mode 160–300 Vac 176–276 Vac
Frequency 50 Hz/60 Hz
±
4 Hz
Power factor λ 0.96 λ 0.98
Current consumption (max.) 7 A 10 A 16 A 31 A 50 A
UPS OUTPUT
Rated output voltage 220 Vac/230 Vac/240 Vac
±
2 % 220 Vac/230 Vac/240 Vac
±
1 %
Frequency in battery mode 50 Hz/60 Hz
±
0.2 % 50 Hz/60 Hz
±
0.1 %
Output current (at 230 Vac) 4.3 A 8.7 A 13 A 26 A 43.4 A
Transfer time at mains outage 0 ms (zero transfer)
Voltage waveform sinusoidal, THD < 4 %
Overload response (online mode) 140 % 30 s/150 % 300 ms 130 % 10 min/>130 % 1 s
subsequent, transfer to bypass mode
Crest factor 3 : 1
Short-circuit response short-circuit-proof
BATTERY
Type sealed, maintenance free
Rated voltage 36 Vdc 96 Vdc 240 Vdc
Overload/deep discharge protection yes yes yes yes yes
Recharge time (to 90 % of rated capacity) 5 h 5 h 5 h 7 h 7 h
COMMUNICATION
Interfaces RS232 for UPS configuration, status and measurement levels, SNMP, AS 400, USB optional
Shutdown software (on CD) Included for all typical operating systems (e.g. Windows, Mac, Linux, Unix, Sun, etc),
single licence CompuWatch with a 5 fold network licence
Failure indicators (acoustical/optical) LED bar graph for UPS load and battery capacity,indicators for mains failure, overload,
battery discharge, battery replace, failure
GENERAL DATA
Efficiency total 85 % 88 % > 90 %
Audible noise (1 m distance) < 45 dB (A) < 50 dB (A) < 55 dB (A)
Operating temperature range 0°–40° C
EMC conformity EN 62040-2 Class C2, EN 61000-3-2, EN 61000-3-3 EN 50091-2
Product safety EN-62040-1
Data lines protection RJ11 (Phone, Fax, Modem) / RJ45 (Ethernet 10 Mbit/s / 100 Mbit/s)
Humidity 0 –90 % (non condensing)
Installation height up to 1000 m, at nominal load
Number of outlets Tower 4 x IEC 320 C13 6 x IEC 320 C13 4 x IEC 320 C13 Terminal block
+ 1 x IEC 320 C19
Equipment colour Blackline
Size approx. W x H x d (mm) Tower 145 x 220 x 400 192 x 340 x 460 260 x 717 x 570
Battery integrated (not at S-version, same dimensions as tower)
Weight approx. Tower 15 kg 34 kg 35 kg 90 kg 93 kg
Battery 19 kg 49 kg 49 kg 86 kg 89kg
Shipment Mains-Cord, 3 load-cords (type C.1000, C.2000, C.3000), communication cable,
management software “CompuWatch”, user-manual
Certification CE