For the fitter
Connection of supplementary heater (ZH) with existing internal room temperature regulator (RTi) . . .
RTi 102 E
Circuit diagram WSP 1210 F - 4810 F with ZH and RTi 102 E
Circuit diagram WSP 3510 N and 5010 N with ZH and RTi 102 E
English
A1: Electronic charging control unit
B1: Core temperature sensor - charging
E1 - E6: Heating element (storage heater)
F1: Safety temperature limiter
F2: Delay-Action Fuse 250 V2A
K1: Thermal relay
M1 - M3: Fan discharge
N4: Temperature limiter - charging
N5: Temperature limiter - discharging
R1: Adjuster – charging (selector knob)
V4: Pilot lamp operation emergency
operation
X1: Mains terminal
X2: Terminal
X3: DC terminal 0.91 – 1.43 V
X16: Control signal adapter 4-stage
X17: Output reducer 4-stage
Special accessories
not included in delivery scope, mark the respective accessory if installed
X
Integr. room temperature regulator 2-position
Integr. room temperature regulator proportional
A2: Electronic discharge control unit
B2: Room temperature sensor discharge
R2: Adjuster discharge (selector knob)
S2: ON/OFF switch room temperature regulator
X
Supplementary heater
E8: Supplementary heating element
N2: Temperature regulator – supplementary heater
N3: Temperature regulator – supplementary heater
S1: ON/OFF switch – supplementary heater
Note the permissible rating of the room temperature regulator
when installing the supplementary heater (E8)!
bk, approx.
420 lg
X = cable harness
electron. charging
control unit
Cu-bridge
bl., approx.
230 lg
electron. discharge control unit
AC-signal 230 V
Charging control signal
DC signal
charging control signal
3/N/PE ~ 50 Hz 400 V
Control circuit
1/N/PE ~ 50 Hz 230 V