2.2.2 Reducing the Output
By moving or removing bridges at the terminals, the connection rating, factory wired to 100 % can
be reduced by three levels (see the table).
The dimensioning of the line cross sections and the fusing should correspond to the maximum
possible output of the unit
A single-phase connection may be made according to the "Technical connection conditions" of
/ 7 \ the energy supply company only up to 2 kW (WSP 2010).
Power
variants kW
8h heating elements
(series)
6h heating element fitt
(special accessory!
ng set
Connection
Ф
(D
® Ф
®
variants
100 o/o
91.6 %
83.3 %
75%
100%
100 %
91.6% 83.3 %
75%
Model
WSP 2010
2.0 1.83
1.67
1.50
2.0
2.7 2.47
2.25
2.03
WSP 3010
3.0 2.75
2.50
2.25
-
4.1
3.75
3.42
3.07
WSP 4010
4.0 3.66
3.33
3.00
-
5.5 5.04
4.58
4.13
WSP 5010
5.0 4.58
4.16
3.75
-
6.5 5.96
5.42
4.88
WSP 6010
6.0 5.50
5.00
4.50
-
8.1 7.42
6.75
6.08
WSP 7010
7.0 6.42
5.83
5.25
-
9.0 8.24
7.5
6.75
О
100 % P ,,
rated
(series wiring)
3
2 1 L3
L2 Ll
XI
IN I L3 I L21 LI
3/N/PE - 50 Hz 400 V
©
91.6% P
я;
L3lL2lLl
3/N/PE - 50 Hz 400 V
83.3 % P
rated
Г
© Г
1
3 2
1
L3 L2 LI
XT
L
3 2
1 L3 L2
LI XI
In lL3lL2lL1
3/N/PE - 50 Hz 400 V
©
75 % P
rated
3
2 1 L3
L2 Ll
XI
Il3 IlzIli
3/PE - 50 Hz 400 V
©
100 % P,,,,. 2kW
3 2
1
L3
L2 Ll
XI
LI
1/N/PE-50 Hz 230 V
2.3 Rules and Regulations
• Pay attention to the packing slip!
The national building and garage regulations must be taken into account
The installation area must have a sufficient floor load capacity.
In case of doubt a building surveyor should be consulted (for weights of the storage heaters, see
"Technical Data").
The minimum distance from adjacent object surfaces must be kept (figs. 2 and 2a).
All electrical connection and installation work must be performed in accordance with the VDE
regulations (0100), the regulations of the electricity supply company responsible and the
pertinent national and regional regulations.
The device must be disconnectable from the mains at all poles by an supplementary device with a
disconnection distance of at least 3 mm. Contactors, fuses and similar can be connected for this.
A later increase in the output must be approved separately by the responsible electricity supply
company. Failure to notify the electricity supply company of the increase in the output
constitutes a breach of the electricity supply contract
The operating equipment must be designed for the rated consumption of the units.
The unit’s rating plate must be observed!
The specified voltage must match the rated voltage.
The unit must be fixed to meet the VDE standing safety requirement