Aeg WSP 7010 User Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 19
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
For the Fitter
A
A bridged must be inserted between "N" and "/KljlT for operation with "single-wire control"**!
Power adaptation according to rated charging time
By moving or removing bridges at the terminals, the output can be adapted to the rated charging
time specified by the electricity supply company.
Heating element model
8h (series)
6h (heating element 1
fitting set)
Rated charging time
8h
9h
lOh
5h
6h
7h
Connection variants (kW)
Model
Ф CD
Ф
(D
WSP 2010
2.0
1.83
1.67
2.7
2.47
2.25
WSP 3010
3.0
2.75 2.5 4.1
3.76
3.42
WSP 4010
4.0
3.66 3.33 5.5
5.04
4.58
WSP 5010
5.0
4.58
4.16
6.5
5.96
5.42
WSP 6010
6.0
5.5
5.0 8.1
7.42
6.75
WSP 7010
7.0 6.42 5.83
9.0
8.24
7.5
8 h
9 h
10 h
©
100 o/o P
rated
(series wiring)
1
Г
L
3
2
1
L3 L2
LI
XI
©3 I L21 LI
3/N/PE-50 Hz 400 V
91.6% P
rated
©
3
2
1
L3 L2
LI
XI
In lL3lL2lL1
3/N/PE-50 Hz 400 V
83.3 % P
rated
©
3
2
1
L3 L2
LI
Mn
XI
L3IL2IL1
3/N/PE-50 Hz 400 V
Ш ’
Unit rating plate
Observe the labelling on the rating plate and the circuit diagram!
After connecting electrically, the box corresponding to the connection rating and rated charging
time of the unit on the rating plate and the circuit diagram in these installation instructions
should be marked with a smear-proof ballpoint pen.
2.5.3 Unit Ready for Operation
Cleaning the unit (fig. 13 and 14)
The open unit must be cleaned after installation and insertion of the storage blocks.
The fans and the air guidance assembly must be removed for this.
Unscrew and remove the air guidance assembly (16)
• Lift and remove the fan (18) after loosening (not removing) the screws at the front of the
support brackets (pay attention to cable laying!).
In some units, the discharge temperature control unit (19) including support plate must be
unscrewed.
Make sure the wires are not damaged when setting down the removed parts.
Clean the floor plate and fan (avoid damage to lamellasi). Then re-install the fans, possibly the
temperature limiter and the air guidance module (correct cable laying!).
Close the unit (fig. 15 and 16)
Hang in the inside front wall with thermal insulation swung forward slightly at an angle at the
top edge and screw at the bottom edge with 2 screws;
• Hang in the right side wall at the bottom, tilt up, hang in at top and fix with screw; (reverse
order see 2.5.1 - disassembly right side wall fig. 6)
• Hang in front wall at top, swing to the heater at the bottom and fix with 2 screws (always use
the two inside threaded holes) (fig. 15);
Screw on the air outlet grille, screwing the screws hand tight and then back about 1 turn
(fig. 16):
• Place the air inlet grille at an angle on the lugs in the heater base, swing round at the top and
snap in behind the air outlet grille (fig. 16).