WARNINGS:
CHOICE OF ELECTRICAL
CONNECTION
There are three possible ways to connect your
appliance. In each case the appliance should be
operated using at least 6mm
2
twin core and
earth PVC insulated multicore cable. Please
choose from the most appropriate after reading
the different methods:-
a) By connecting the appliance to a cooker point
(having a double pole isolating switch with at
least 3mm contact separation in all poles and
neutral) and protected with a fuse or miniature
circuit breaker at your mains fuse box.
b) By connecting the appliance together with a hob
directly to a cooker point(s). Having a double
pole isolating switch with at least 3mm contact
separation in all poles and neutral.
c) If you wish to connect an oven and a hob to a
cooker point you can by connecting the oven
and hob separately to the cooker point. Oven
and hob units should be separately connected
to a control panel. See Fig. 2.
31
This appliance must be installed by a
qualified electrician/competent
person. Safety may be impaired if
installation is not carried out in
accordance with these instructions.
This appliance must be earthed.
Do not remove the screws from the
earth tab extending from the oven
mains terminal block (Fig.1).
Before connecting the appliance
make sure that the voltage of your
electricity supply is the same as that
indicated on the rating plate. This is
situated on the lower front frame of
the oven and can be seen upon
opening the main cavity door.
Alternatively the rating plate may also
be found on opening the back or top
or top of some models (where
applicable)
Do not alter the electrical circuitry of
this appliance.
Subject to Regional Electricity Company
regulations if you wish to connect the
oven and hob to the power supply you
may use one of the following two
methods:-
Fig. 2
Red or
Brown
Blue or
Black
5mm
Mains
Cable
Earth Tab
Earth (Green or
Green/Yellow)
Fig.1