Figure 4.9
Connecting the actual-value display
Note: at 10 V, display shows 100.0 (%)
The decimal point is set at the factory for a 100.0 (%)
display range.
NOTE
NOTE: Electromagnetic compatibility: shield the signal
lines for the actual-value
display if line lengths exceed 5 metres.
4.2.7 Switching On/Off Externally
The connector set can be externally switched on or off by
means of a switch (relajl buttons or optical coupler. The
corresponding binding post assignments are shmj in
Figure 4.10. Requirements for the external switching
element:
• voltage-free contacts
precision contacts for 10 V DC
maximum load 5 mA
ATTENTION! Destruction of the connector set: do not
connect voltage to binding posts 21, 22 or 23!
ATTENTION!