AEG DDLE Basis 13 Operations Instructions Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 17
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
31
For contractors
s $IRECTTAPINSTANTANEOUSWATERHEATERS
ADEo 70 WD - mono-lever mixer tap with changeover bath/hand shower
Part no. 18 39 34
s )NSTALLATIONACCESSORIES
Pipe assembly undersink installation UT 104
Part no. 18 44 21
Water connections with 12 mm compression fittings
s 5NIVERSALMOUNTINGFRAME
Part no. 22 77 01
Comprising:
Mounting frame with
– electrical wiring.
This assembly creates a gap of 30 mm between the device back panel and the installation wall.
This enables the power supply to be routed over unfinished walls at any point behind the device. This
increases the equipment depth by 30 mm. This set reduces the protection to IP 24 (splash-proof).
s /FFSETINSTALLATIONSETFORUNlNISHEDWALLS
Part no. 22 77 02
Comprising:
Universal mounting frame (for technical description, see part no. 22 77 01).
Pipe bends for a vertical offset of the device relative to the water connection by 90 mm downwards.
s 0IPEASSEMBLYREPLACEMENTOFAGASlREDWATERHEATER
Part no. 22 77 03
Comprising:
Universal mounting frame (for a technical description see part no. 22 77 01)
Pipe bends for the installation with existing gas water heater connections
(cold water on the left and DHW on the right).
s -AXIMUMDEMANDRELAY,2!
Part no. 00 17 86
Priority control of the instantaneous water heater when operating, for example, electric storage heaters
simultaneously. For connection of the LR 1-A, see
L
.
8. Special accessories
No hot water; throughput
> 3 l/min
Traffic light display:
constant yellow indication
green flashing
High limit safety cut-out triggered or
cable break
Heating system faulty
Faulty electronics
Check high limit safety cut-out and
activate, if required (
A
15).
Test the heating system resistor (
A
16)
and replace, if required.
Test the electronics PCB (
A
7) and
replace, if required.
No hot water
Traffic light display:
constant red illumination
green flashing
Cold water inlet temperature > 35 °C
Flow rate > 25 l/min
Cold water sensor faulty
Reduce the temperature of the cold water
supply to the device.
Reduce the device throughput.
Test the electronics PCB (
A
7) and
replace, if required.
Table 6
Page view 13
1 2 ... 9 10 11 12 13 14 15 16 17

Comments to this Manuals

No comments