If the hose is long and the
room temperature low, the
moisture might condense to
water inside the hose. This is
an usual occurrence. To
prevent this water from the
hose, it is recommend to
drill a small hole (via. 3 mm)
in the lowest point of the
hose and to put a small
container below it. (See
picture, point B).
B
Installation
There are 3 vent outlets: on
the left, right side and at the
rear.
1. Pull the ring nut A from the vent
outlet at the rear.
A
A
2. Screw on the ring nut to the hose
and push it into position.
A
3.
The not used vents must be sealed
with supplied covers.
15.3 Load door reversal
WARNING!
Before changing the door
stop, disconnect the mains
plug.
Note regarding contact
protection: The appliance is
only secure for operations
again once all plastic parts
have been put.
1. Open load door.
2. Unscrew hinge A from the front of
the appliance and remove the load
door.
3. Remove cover plates B. To do this,
put a thin screwdriver into the slots
as shown in the illustration, push
down lightly and remove the cover
plates.