AEG L8WEC166R User Manual Page 44

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 43
Programmes Load
(kg)
Energy
consump-
tion (kWh)
Water con-
sumption (li-
tre)
Approximate pro-
gramme duration
(minutes)
Cottons Eco
Cotton Energy Saving Pro-
gramme 60°C
1)
10 0.86 61 265
Cottons 40°C 10 1.10 90 220
Synthetics 40°C 4 0.72 55 155
Delicates 40°C 4 0.60 59 89
Wool/Handwash 30°C 2 0.35 58 60
1)
«Cotton Energy Saving programme » at 60°C with a load of 10kg is the reference programme for the
data entered in the energy label, in compliance with 96/60/EC Directive.
18. TECHNICAL DATA
Dimension Width/ Height/ Depth/
Total depth
600 mm/ 850 mm/ 630 mm/ 660 mm
Electrical connection Voltage
Overall power
Fuse
Frequency
230-240 V
2200 W
13 A
50 Hz
Level of protection against ingress of solid particles
and moisture ensured by the protective cover, ex-
cept where the low voltage equipment has no pro-
tection against moisture
IPX4
Water supply
1)
Cold water
Water supply pressure
2)
Minimum
Maximum
0.5 bar (0.05 MPa)
8 bar (0.8 MPa)
Maximum wash load Cotton 10 kg
Maximum dry load Cotton
Synthetics
6 kg
4 kg
Spin Speed Maximum spin speed 1550 rpm
1)
Connect the water inlet hose to a water tap with a 3/4'' thread.
2)
The appliance works correctly if the water pressure is not lower than 0.05 MPa (0.5 bar). If you cannot
connect the water inlet hose to the cold water tap of the primary hydraulic system, connect it to your
domestic cold water storage system. Make sure not to exceed a distance of 5.02 m (16.5 ft) between the
appliance inlet hose and the bottom of the water storage tank.