www.aeg.com
Dirty air lter - air restricted. Clean air
lter.
Outside temperature extremely hot.
Set FAN speed to a faster setting to
bring air through cooling coils more
frequently.
Room too cold.
Set temperature too low. Increase set
temperature.
Air conditioner cooling, but room is
too warm - ice forming on cooling
coil behind decorative front.
Air conditioner turns on and o
rapidly.
Dirty air lter - air restricted. Clean air
lter. Refer to 8. Care and Cleaning
section.
Temperature is set too high. Set
temperature to a lower setting.
Air directional louvers positioned
improperly. Position louvers for better
air distribution.
Front of unit is blocked by drapes, blinds,
furniture, etc. - restricts air distribution.
Clear blockage in front of unit.
Doors, windows, registers, etc. open -
cool air escapes. Close doors,
windows, registers, etc.
Unit recently turned on in hot room.
Allow additional time to remove
“stored heat” from walls, ceiling,
oor and furniture.
10.
ENVIRONMENTAL CONCERNS
Recycle the materials with the symbol.
Put the packaging in applicable
containers to recycle it. Help protect the
environment and human health and to
recycle waste of electrical and electronic
appliances. Do not dispose appliances
marked with the symbol
with the
household waste. Return the product
to your local recycling facility or contact
your municipal oce.
Page view 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 91 92

Comments to this Manuals

No comments