6. INVERTER STATUS
Protect PV is designed to be user-friendly; therefore, the status of the
Inverter can be easily understood by reading the information shown
on the front panel display. All possible messages are shown in the
following table.
DISPLAY INFORMATION
OPERATING CONDITIONS MESSAGE DESCRIPTION
NORMAL WORKING STATUS
Power off No display
PV inverter is totally
shutdown, VPV <=70V
Standby STANDBY 90V< Input voltage < =100V
Initialization & waiting READY
Input voltage range 100~150V
during start-up. After PV
voltage is higher than 100V,
inverter is waiting for feeding
to grid
Check grid CHECKINGxxxs
When PV voltage> 150V,
inverter is checking feeding
conditions
Feeding grid, MPPT GRID CONNECTED
Inverter is feeding power. After 10
seconds of this display, LED will show
wattage.
FLASH FLASH FLASH-firmware
Today energy Etoday=xxx.xxkWh
Total energy to has been fed
to grid since today
MONITORING PARAMETERS
Instantaneous
Output power
Pac=xxx.xW The real time output power in xxxx W
Accumulated energy
information
Etot=xxxxxxkWh
Total energy to has been fed
to grid since inverter was
installed
Grid voltage Vac=xxx.xV Grid voltage in xxx.x VAC
Grid frequency Fac=xx.xHz Grid frequency in xx.x Hz