AEG 6561G-M User Manual Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 21
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
19
Cable type: 0,75 mm² HO5 V2V2-F
The Dropinett must be connected via
an external switch with a contact
gap of min. 3 mm (the main switch
may be used)
Wiring
Type of gas
Adjusted to natural gas: G20 - 20 mbar
Category and pressures
II
2H3B/P
Convertible to
Bottled gas - G30 - 30 mbar
Max. nominal load Q na H
S
:
Small sized burner= 1,0 kW x 1
Medium sized burner = 1,9 kW x 2
Large sized burner = 2,7 kW x 1
Total= 7,6 kW
FSD
The unit features fully-secured gas
taps (thermo-fuse).
H
S
= Top calorific value
Q = Nominal load
ID. CE-048AU-0003
Ignition transformer= 50 HZ - 0,6 VA
Radio-noise reduction
This unit observes the current EEC-
directive on radio noise reduction.
This gas appliance is -approved and
marked in accordance with the gas
appliance Directive (90/396/CEE), the
low voltage directive (73/23/CEE) and
the EMC directive (89/336/CEE incl.
the agreed directive changes.
Technical data
HO5V2V2-F
Yellow/Green: 61 mm +/- 3 mm
Blue and brown: 51 mm +/- 3 mm
N L1
240 V
1N + PE
Page view 18