End charging process
1. Unplug from the AC outlet.
2. Disconnect the charging clamp (black) from the vehicle’s body, in exceptions
from the negative battery terminal (marked N or -).
3. Disconnect the positive charging clamp (red) from the positive battery terminal
(marked P or +).
maintenancecharge
14.2
14.7
13.5
12
10.5
7.4 - 8A
6.3 - 7A
4.3 - 5.2A
1.8 - 2.7A
<1A
13.7(v)
14.2 - 14.7(v)
13.5- 14.2(v)
13.0- 13.5(v)
10.5- 12.5(v)
Time "t"