5.
Clean the dispenser recess with a
brush.
6.
Put back the dispenser in the recess.
13.7 Drain pump
Regularly examine the drain
pump and make sure that it is
clean.
Clean the pump if:
The appliance does not drain the wa-
ter.
The drum cannot turn.
The appliance makes an unusual noise
because of the blockage of the drain
pump.
The display shows an alarm code be-
cause of the problem with water drain.
WARNING!
1.
Disconnect the mains plug
from the mains socket.
2.
Do not remove the filter
while the appliance oper-
ates. Do not clean the drain
pump if the water in the ap-
pliance is hot. The water
must be cold before you
clean the drain pump.
To clean the drain pump:
1.
Open the drain pump door.
2.
Pull the flap out to remove it.
3.
Put a container below the recess of
the drain pump to collect the water
that flows out.
4.
Press the two levers and pull for-
ward the drainage duct to let the
water flow out.