WARNING!
Before unscrewing the pump
cover, switch the appliance
off and remove the mains
plug from the socket.
WARNING!
When the appliance is
operating and depending
on the programme selected
there can be hot water in the
filter. Never remove the filter
cover during a wash cycle.
Always wait until the
appliance has finished the
cycle and it is empty. When
refitting the filter cover,
ensure it is securely re-
tightened so as to stop leaks
and young children being
able to remove it.
To clean the drain filter:
1. Unplug the appliance.
2. If necessary, wait until the water has cooled down.
A B
3. Place a container close to the pump to
collect any spillage.
A = Cover filter.
B = Emergency emptying hose.
4. Release the emergency emptying hose,
place it in the container and remove its cap
cover.
1
2
5. When the water stops flowing, unscrew the
filter cover by turning it anti-clockwise and
remove the filter. Use pliers if necessary.
Always keep a rag nearby to dry up any water
spillages when removing the cover. Clean the
filter under a tap to remove any traces of fluff.