  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 26
find this plate in the package sup-
plied with the appliance.
If the supply gas pressure is changeable
or different from the necessary pressure,
you must fit an applicable pressure ad-
juster on the gas supply pipe.
8.3 Adjustment of minimum
level
To adjust the minimum level of the burn-
ers:
1.
Light the burner.
2.
Turn the knob on the minimum posi-
tion.
3.
Remove the knob.
4.
With a thin screwdriver, adjust the
by-pass screw position.
A
A)
The by-pass screw
If you change from natural gas G20/
G25 20/25 mbar to liquid gas, fully
tighten the by-pass screw in.
If you change from liquid gas to natu-
ral gas G20/G25 20/25 mbar, undo the
by-pass screw approximately 1/4 of a
turn (1/2 of a turn for Triple Crown
burner).
WARNING!
Make sure the flame does not go
out when you quickly turn the
knob from the maximum position
to the minimum position.
8.4 Electrical connection
Ground the appliance according to
safety precautions.
Make sure that the rated voltage and
type of power on the rating plate
agree with the voltage and the power
of the local power supply.
This appliance is supplied with a mains
cable. It has to be supplied with a cor-
rect plug, able to support the load
marked on the rating plate. The plug
has to be fitted in a correct socket.
Any electrical component must be in-
stalled or replaced by the Service
Force Centre technician or qualified
service personnel.
Always use a correctly installed shock-
proof socket.
Make sure that there is an access to
the mains plug after installation.
Do not pull the mains cable to discon-
nect the appliance. Always pull the
mains plug.
The appliance must not be connected
with an extension cable, an adapter or
a multiple connection (risk of fire).
Check that the ground connection is
in conformity with the standard and
regulations force.
The power cable must be placed in
such a way that it does not touch any
hot part.
Connect the appliance to the mains
with a device that lets to disconnect
the appliance from the mains at all
poles with a contact opening width of
minimum 3 mm, eg. automatic line
protecting cut-out, earth leakage trips
or fuse.
None of a parts of the connection ca-
ble can not get a temperature 90 °C.
The blue neutral cable must be con-
nected to the terminal block label with
"N". The brown (or black) phase cable
(fitted in the terminal block contact
marked with "L") must always be con-
nected to the live phase.
8.5 Replacement of the
connection cable
To replace the connection cable use on-
ly H05V2V2-F T90 or equivalent type.
Make sure that the cable section is appli-
cable to the voltage and the working
temperature. The yellow/green earth
wire must be approximately 2 cm longer
than the brown (or black) phase wire.
ENGLISH 27