Page view 24
N 560-568 mm
115 mm
20
mm
442 mm
180
mm
A 595
mm
N 600
mm
A 592 mm
A 567
mm
N min.
550 mm
~50 mm
A A
B
3. Use a minimum of 2 screws to attach
the oven on the 2 sides (A).
When installing next to a wood-
fuelled boiler, a heat-proof and heat-
insulating plate must be mounted at
the height of the appliance and at
least 30 cm deep.
A B
A
min. 20 mm
10
mm
20 mm
13.4 Electrical connection
WARNING!
If service is required always
disconnect the appliance
from the power supply.
Use a power cable of H05VV-F or higher.
Install the appliance with a socket supply
line. If there is no socket supply line, the
fixed home electrical system must
include an isolating device with at least a
3 mm-contact separation to enable a
simultaneous and all-pole cut off from
the mains (according to NIN SEV 1000).
The customer must have a socket for the
electrical connection that is accessible
and outside the coordination room. The
length of the connection cable must be
approximately 120 cm with lines
connected directly to the mains.
Only a qualified person can
connect the appliance to the
electricity supply.
1. Do the electrical connections as in
the connection illustration.
Phase definitions: L1, L2 (or R, S).
Voltage: 400V
L2 N
L1PE
400V 2N~
400V
1
5 4
2 3
2. Secure the cable grip.
1
2
ENGLISH