AEG F34300VI0 User Manual Page 53

  • Download
  • Add to my manuals
  • Print
  • Page
    / 60
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 52
Problem and alarm code Possible cause and solution
The appliance does not fill with water.
The end indicator flashes 1 time in-
termittently.
Acoustic signal sounds 1 time in-
termittently.
Make sure that the water tap is open.
Make sure that the pressure of the water sup-
ply is not too low. For this information, contact
your local water authority.
Make sure that the water tap is not clogged.
Make sure that the filter in the inlet hose is not
clogged.
Make sure that the inlet hose has no kinks or
bends.
The appliance does not drain the wa-
ter.
The end indicator flashes 2 times
intermittently.
Acoustic signal sounds 2 times in-
termittently.
Make sure that the sink spigot is not clogged.
Make sure that the drain hose has no kinks or
bends.
The anti-flood device is on.
The end indicator flashes 3 times
intermittently.
Acoustic signal sounds 3 times in-
termittently.
Close the water tap and contact an Authorised
Service Centre.
The appliance stops and starts more
times during operation.
It is normal. It provides optimal cleaning re-
sults and energy savings.
The program lasts too long. If the delayed start option is set, cancel the de-
lay setting or wait for the end of the count-
down.
Small leak from the appliance door. The appliance is not level. Loosen or tighten
the adjustable feet (if applicable).
The appliance door is not centred on the tub.
Adjust the rear foot (if applicable).
The appliance door is difficult to
close.
The appliance is not level. Loosen or tighten
the adjustable feet (if applicable).
Parts of the tableware are protruding from the
baskets.
Rattling/knocking sounds from inside
the appliance.
The tableware is not properly arranged in the
baskets. Refer to basket loading leaflet.
Make sure that the spray arms can rotate free-
ly.
The appliance trips the circuit-beaker. The amperage is insufficient to supply simulta-
neously all the appliances in use. Check the
socket amperage and the capacity of the me-
ter or turn off one of the appliances in use.
Internal electrical fault of the appliance. Con-
tact an Authorised Service Centre.