Page view 39
16.3 Installation on suspended
flooring
Suspended wooden floors are
particularly susceptible to vibration.
To help prevent vibration we
recommend you place a waterproof
wood panel, at least 15 mm thick under
the appliance, secured to at least 2 floor
beams with screws, the wood panel must
extend beyond the front feet.
If possible install the appliance in one of
the corners of the room, where the floor
is more stable.
16.4 Installation under a counter
600 mm
600 mm
870 mm
The appliance can be installed as
freestanding or below the kitchen counter
with correct space (see picture).
CAUTION!
To assure free air circulation
under the appliance, do not
attach the sound barriers (if
available).
16.5 Positioning and levelling
x4
Install the appliance on a flat hard floor.
Make sure that carpets do not stop the air
circulation below the appliance.
Make sure that the appliance does not
touch the wall or other units.
Loosen or tighten the feet to adjust the
level.
A correct adjustment of the appliance level
prevents the vibration, noise and the
movement of the appliance when in
operation.
The appliance must be level and stable.
CAUTION!
Do not put cardboard, wood
or equivalent materials below
the appliance feet to adjust
the level.
www.aeg.com40